What was found
FWD CARGO FRAME 30 UPPER FLOORBEAM BETWEEN S/T 2R AND 3R IS CRACKED ON FWD SIDE. PERFORMED CROSSBEAM REPAIR AT FWD FACE OF FLOORBEAM FRAME 30 BETWEEN SEAT TRACK 2R AND 3R BY REMOVING DAMAGE, FABRICATING, LOCATING AND DRILLING A FILLER AND REPAIR CHANNEL AND INSTALLING IAW SRM 51-75-10, SRM 51-21-10, SRM 53-10-15 FIGURE 212, NTM 51-10-08.