As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT PIT STRINGER HAS DOUBLE DRILLED HOLES STA 970 STR 28L REMOVED PREVIOUS REPAIR SPLICE AND PRODUCTION SPLICE, REMOVED DAMAGED STRINGER SECTION, LOCATED AND DRILLED NEW STRINGER SECTION USING BAC1498-145 7075T-6 PO 29057141 DIMS 43.1250" AND INSTALLED NEW STRINGER SECTION AND EXISTING REPAIR SPLICE AND PRODUCTION SPLICE IAW SRM 53-10-2, 51-30-5, 53-10-3 AND 51-30-2.