What was found
STR 25L AT STA 1650 HAD DEFORMED HOLE. R & R STRINGER AT STA 1650 S-25L IAW SRM 53-00-03 FIG 201, REPAIR 1 DETAIL II. FOUND HOLE TO BE OUT OF LIMITS IAW SRM 53-00-03, FIG 101. CLASSIFIED CATEGORY "A" MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STR 25L AT STA 1650 HAD DEFORMED HOLE. R & R STRINGER AT STA 1650 S-25L IAW SRM 53-00-03 FIG 201, REPAIR 1 DETAIL II. FOUND HOLE TO BE OUT OF LIMITS IAW SRM 53-00-03, FIG 101. CLASSIFIED CATEGORY "A" MAJOR REPAIR.