What was found
LT WING - STA XORS 690 TO XORS 700 LOWER SKIN ACCESS DOOR CUT OUT 08 EACH FASTENER HOLES FOUND CRACKED DURING HFEC OPEN HOLE INSPECTION. LT WING - STA XORS 690 TO XORS 700 LOWER SKIN ACCESS DOOR CUT OUT 08 EACH. FASTENER HOLES REPAIRED IAW EA NR 1-5710-132403, TITLE: AD 2007-07-04 - WINGS - LT LOWER SKIN PLANK CUT OUT AT 536AB - REPAIR TO ACCESS DOOR ATTACHMENT BORES WITH CRACK INDICATIONS PSE 57.23.01 ALI. REPAIR CLASSIFIED AS MINOR IAW GMM 6-2-100, REV 110.