What was found
RT WING - STA XORS 690 TO XORS 700 LOWER SKIN ACCESS DOOR CUT OUT 09 EACH FASTENER HOLES FOUND CRACKED DURING HFEC OPEN HOLE INSP. RT WING - STA XORS 690 TO XORS 700 LOWER SKIN ACCESS DOOR CUT OUT 09 EACH FASTENER HOLES REPAIRED IAW EA NR 1-5710-132404, TITLE: AD 2007-07-04 WINGS - RT LOWER SKIN PLANK CUT OUT AT 636AB - REPAIR TO ACCESS DOOR ATTACHMENT BORES WITH CRACK INDICATIONS, PSE 57.23.01 ALI. REPAIR CLASSIFIED AS MINOR IAW GMM 6-2-100, REV 110.