What was found
FRAME AT STA 395.5, STR 6R IS CRACKED AT STRINGER CLIP HOLE. CRACK ON FRAME BS 395, S6R, FOUND TO BE OUT OF LIMITS IAW SRM 53-00-07, FIG.101, NOTE "A". FABRICATED NEW FRAME SEGMENT ON TRAVELER NR T10/828685. INSTALLED NEW FRAME SEGMENT AT BS 395, S4-10R, IAW SRM 51-40-02/51-10-02.