What was found
ALTITUDE WAS CLIMBING UNCONTROLLABLE CABIN WITH OUTFLOW VALVE CLOSED/DESCENDED TO FL190 IN ORDER TO MAINTAIN A CABIN ALTITUDE BELOW 100,000 FT. COMPLIED WITH QRH AND RAN PRESSURIZATION ON STBY AND MANUAL WITH NO CHANGE. R & R RUBBER SEAL JUST AFT OF THE ACM, IAW SMP. RESEALED AREA'S AROUND AFT LOWER MAIN CARGO DOOR, IAW SMP. OPS CHECK CABIN PRESSURE SYS IAW JRH CHPT, SECTION 8-47. ALL CHECKS GOOD.