What was found
LOWER STUB FRAME EXTENSIONS, BS 580, STR 21L - 22L, CRACK ON RADIUS CUT OUT. REMOVED STUB FRAME AT BS 580 BETWEEN STR 21L AND 22L IAW SRM, REV 102, 51-30-2. FABRICATED STUB FRAME USING 7075 - 0, .063" X 6" X 17" IAW SRM 51-20-1 FIG. 7 AND DWG NR 53FX1350. INSTALLED STUB FRAME IAW SRM 51-30-2.