What was found
LT LOWER STAIR WELL TORQUE BOX BS 1228 HAS LIGHTENING HOLE CRACK. ROUTED OUT DAMAGED AREA .1875" X .5" IAW SRM, REV 102, 51-10-1. FABRICATED DOUBLER FROM MATERIAL 7075 T-6, .032" X 1" X 4" IAW SRM 53-10-2 FIG 6 AND 51-40-2 FIG 1. INSTALLED REPAIR DOUBLER IAW SRM 51-30-2.