What was found
AFT CARGO PIT MDC FLOORBEAM FR 54.3 BETWEEN SEAT TRACK 2R-3R, CRACK LENGTH IS 0.125 IN ROUTED OUT CRACK FABRICATED, TREATED AND PRIMED AND INSTALLED REPAIR CHANNEL AT AFT CARGO PIT MDC FLOORBEAM FR 54.3 BETWEEN SEAT TRACK 2R-3R IAW SRM 53-10-15, PG 257-258, FIG 204.