What was found
RT EMERGENCY SLIDE DEPLOYED ON THE GROUND. ANC R RELEASED FOR SERVICE IAW MEL: 52-11-01-02 CATEGORY: C EXPIRATION: 07MAY10 "MEL 52-11-01-02: DOOR (R1 SLIDE/RAFT-INOP) IF SLIDE/RAFT TO BE RETAINED ONBOARD THEN PRIOR TO EACH DEPARTURE MX MUST VERIFY SLIDE STOWED ACCORDING TO PROCEDURES. NOTE: SLIDE DID NOT INFLATE, ONLY CAME OUT OF PACK, UNABLE TO GET SLIDE BACK IN PACK DUE TIME, SLIDE IS NOW REMOVED FROM ACFT EA G-5220-140125, ACFT K FOR SERVICE. REMOVAL FROM ACFT ONLY **NO INSTALLATION** INSTALLED R-1 ESCAPE SLIDE IAW MM 25-66-01-4. OP'S CK GOOD. NOTE: R-I DOOR PRESSURE RESERVOIR HAS NO AIR PRESSURE. ITEM REMAINS DEFERRED. REF. WRI NR 25-60-0494 FOR MSN INFO FOR PRESS. RESERVOIR.