What was found
OUTWARD SKIN DENT ON EXTERNAL SKIN AT STA 1800 APPROX 5" BELOW S-25R. EVALUATED DENT AT STA 1800 BETWEEN S-25R TO S-26R. A=.415 Y=.015 A/Y RATIO =27. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-01, FIG 101, DETAIL III. REPAIRED DAMAGE IAW SRM 53-00-01, FIG 201 REPAIR 3. SUPPLEMENTAL INSP REQUIREMENT WITH AN INSP THRESHOLD OF 37,500 FC AND REPEAT INSP EVERY 6,000 FC USING HFEC INSP METHOD. CLASSIFIED CATEGORY "B" MAJOR REPAIR.