What was found
NR 2 ENG /PYLON---PYLON WEB STRUCTURE IS CRACKED IN 2 PLACES AS SEEN THROUGH NACELLE ACCESS PANEL 421 CL. STOP DRILLED CRACKS IAW SRM 54-52-11. INSTALLED REPAIR IAW SRM 54-21-11, FIG 201, PGS 205 / 206, CONFIG 2 AND SRM 51-40-30. DISPLACED AND REINSTALLED WIRE BUNDLE IAW SRM 51-40-21, PARA 5. DISCONNECTED AND REINSTALLED GROUND WIRES ON UPPER PYLON AFT WALL IAW ESPM 20-23-11-0. OPS CHECK GOOD ON ENGINE BLEED AIR SYS IAW AMM 36-11-00-5. PERFORMED NR 2 ENGINE IDLE CHECK IAW AMM 71-00-00, CHECKS GOOD..