What was found
SPLICE DOUBLER CRACKED - NR 7 SLAT T/E CHORD ANGLE BENEATH TAI DUCT, APPROXIMATE WING STA 619. REMOVED T/E CHORD ANGLE OF NR 7 SLAT IAW SRM, REV 102, 51-30-2. LOCATED, DRILLED, DEBURRED AND TRIMMED CHORD ANGLE, 114" LONG, IAW SRM 57-50-2 FIG 2 AND 51-30-5. INSTALLED CHORD, FABRICATED FROM BAC1514-1559, 2024-T3, 114" LONG IAW SRM 51-30-2.