What was found
MAIN CABIN UNDER FLOOR PANEL FLOOR SUPPORT FITTING IS CRACKED AT FRAME 49, RBL 57. REPLACED FLOOR SUPPORT LINK IAW SRM 51-72-10, PGS 1-4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CABIN UNDER FLOOR PANEL FLOOR SUPPORT FITTING IS CRACKED AT FRAME 49, RBL 57. REPLACED FLOOR SUPPORT LINK IAW SRM 51-72-10, PGS 1-4.