What was found
AFT PIT BS 1183, VERTICAL BEAM AT LBL 17.8 HAS FASTENERS WITH ZERO SPACING. TRIMMED OUT BEAM AFT FLANGES AND BULKHEAD WEB 8 PLACES IAW EA 7-5310-135541. FABRICATED REPAIR DOUBLER, REPAIR ANGLES, FILLERS, BULKHEAD WEB FILLERS, STRAP DOUBLER, STIFFENER SHIMS, STRUCTURAL FILLERS, SUPPORT ANGLES AND REPAIR TEE IAW EA 7-5310-135541. INSTALLED REPAIR PARTS IAW EA 7-5310-135541 AND SRM 51-30-2.