As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
R-3 DOOR LOWER SILL CREASE BEAM CORRODED AT STA 1320 TO 1360, RBL 60. REMOVED CORROSION ON CREASE BEAM CHORD STA 1320-1360 RLB 60 IAW SRM 51-10-02. FOUND OUT OF LIMITS IAW SRM 53-60-13 FIG 101 DETAIL II. ORIG MATERIAL .071 AFTER REWORK .053 L=.072 W= .053. R & R CHORD IAW SRM 51-40-02. CLASSIFIED CATEGORY "A" MAJOR REPAIR.