What was found
FRAME AT BS 1600, S26L, IS DAMAGED. (IN-PROCESS; AWF FOR REPAIR PARTS) DAMAGED FRAME STA 1600 STR 26L FOUND OUT OF LIMITS IAW SRM 53-00-07 PG-103 FIG. 101 DET. II. ORIG. MAT. .063" MAT. REMAIN .053" MAT. LOSS .010" L=1.0" W=2.0" FABBRICATED & INSTALLED J-SECTION W/TRAVELER T10/835210 IAW SRM 53-00-07 PG 204 FIG 201 DET I & SRM 51-40-20. CAT. "B" REPAIR WITH SUPPLEMENTAL INSPECTION REQUIREMENTS. LINITIAL 50,000 F/C, REPEAT EVERY 12,000 F/C, METHOD-HFEC PER 575 NDT MANNAL 51-00-01 PT6. MAJOR REPAIR