What was found
FUSELAGE SKIN DENT, 2EA, AT BS 330, 2" BELOW S22R, ARE OUT OF LIMITS. (IN-PROCESS: REPAIR IS REQUIRED) EVALUATED UPPER DENT IAW SRM 53-00-01, FIG 101,DETAIL 3 AND FOUND TO BE W/I LIMITS ; A=.742",Y=.011",A/Y=67.45. EVALUATED LOWER DENT IAW SRM 53-00-01, FIG 101, DETAIL 3 AND FOUND TO BE OUT OF LIMITS DUE TO BEING LOCATED COMMON TO THE STRINGER. REPAIRED LOWER DENT IAW SRM 53-00-01, FIG 201,REPAIR NR 2 AT BS 330, S22R. CAT. "B" MAJOR REPAIR WITH THE FOLLOWING TRACKING; INITIAL INSP AT 37,500 FC, THEREAFTER EVERY 6,000 FC (HFEC).