What was found
DENT ON RT FUSELAGE AT FS 524 STR 25R CUT-OUT DAMAGED AREA DIMS 3" X 3", FABRICATED DOUBLER USING 2024T-3 .071 DIMS 12.5" X 10", FILLER USING 2024T-3 .063 DIMS 3" X 3", SHIMS USING 2024T-3 .016 DIMS 8.75" X 5", 14.25" X 5.75", AND 3.5" X 3.5", 2 EACH TAPER SHIMS USING 2024T-3 .071 DIMS 5" X 1" EACH, STRINGER SHIM USING 2024T-3 .016 DIMS 5" X 1" AND INSTALLED ALL REPAIR PARTS IAW SRM 53-00-01.