What was found
STA 1676 3" INBD OF STR. 28R FUSE SKIN DENTED. CHECK DENT LIMITS FOUND TO BE OUT OF LIMITS, DEPTH "Y" .131 MAX ALLOWABLE IS .125 IAW SRM 53-00-01 DETAIL 3, REPAIRED DENT DAMAGE IAW SRM 53-00-01 FIG 201, REPAIR 7, THIS IS CATEGORY "B" REPAIR AND MUST BE INSPECTED AT 24,000 FLT CYCLES AND 12,000 FLT CYCLES THERE AFTER.HFEC INSPECT IAW NDT MANUAL PART 6 51-00-01. THIS IS A MAJOR REPAIR.