What was found
FUS SKIN DENTED APPROX STA 1635 2" ABOVE STR 24R EVALUATED DENT AT STA 1635 2" ABOVE S-24R A=1.0 Y=.040 A/Y RATION=40. FOUND OUT OF LIMITS IAW SRM 53-00-01 FIG 101, DETAIL III. REPAIRED DENT IAW SRM 53-00-01, FIG 201, REPAIR 3 CATEGORY "B" REPAIR WITH SUPPLEMENTAL INSP THRESHOLD OF 25,000 FC WITH REPEAT INSP OF 6,000 FC IAW SRM 53-00-01, FIG 201, REPAIR 3 NOTES H,I, AND TABLE V.