What was found
STA 1600 FLOORBEAM SCRATCHES AND GOUGES FROM BL0 TO RBL 60. REMOVED SCRATCHED AND GOUGED AREAS IAW SRM 51-10-02, ORIG MAT .125 AFTER .115", MEASURED AREA L=24:00" X W=2.00", X DEPTH 0.010", FOUND OUT LIMITS IAW SRM 53-00-51, PAGE 103, FIG 101, DETAIL III, REMOVED AND REPLACED FLOORBEAM AT STA 1600, PN BAC 1548-338/18, BATCH 0001671872, IAW SRM 53-30-51, FIG 1, SH 5 OF 6, AND PER DWG 146N5087. MAJOR REPAIR.