What was found
TOOLING DAMAGE LOCATED AT FR14, STRINGER 12L COMPLIED WITH REPAIR ON FR14 AT STR 12L IAW EA 6-5310-135211, BY SMOOTH REWORK AREA , PERFORMING DVI IAW NTM 51-10-08 ENSURING NO DAMAGE EXIST , PERFORMED ROTOTEST INSP IAW NTM 51-10-01, IMPROVED SURFACE ROUGHNESS NEAR FASTENER HOLES, PERFORMED SPOT FACING IAW SRM 51-71-80 , PERFORMED A DVI IAW NTM 51-70-00 AND ROTOTEST IAW NTM 51-10-01 AND NTM 51-10-18 . REINSTALLED FASTENERS REF PROPER INSTRUCTIONS.