As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ENLOGATED HOLES FOUND IN INCOMING SKIN ALONG STR 26L LAP SPLICE STA 520-640 COMPLY WITH ATTACHMENT "B" OF E.O. F-5100-7-5001 PT 1. REF E.A. F-5330-131197 FOR FOLLOW-UP TRACKING REQUIREMENTS, AS SUCH REPAIR IS CLASSIFIED AS A MAJOR REPAIR IAW GMM 6-2-100.