As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
STA 1240 FLOORBEAM SCRATCHED AND GOUGED FROM RBL 25 TO LBL 60. BLENDED AREA IAW SRM 51-10-02,ORIGINAL MAT =.125 IN AFTER BLEND = 090 IN WHICH IS OUT OF LIMITS IAW SRM 53-00-51. REMOVED AND REPLACED FLOOR BEAM. LOCATED AND DRILLED NEW FLOORBEAM IAW SRM 51-40-05, PRIMED AND PAINTED IAW SRM 51-20=01. INSTALLED FLOORBEAM IAW SRM 51-40-02