What was found
FASTENER WITH IMPROPER SPACING STA 344 STR 5L. TRIMMED OUT DAMAGED AREA DIM .750" CYLINDRICAL. FABRICATED 2EA CYLINDRICAL FREEZE PLUGS FROM 2024 T3 .112" AND .76" DIM .750". FABRICATED REPAIR DOUBLER FROM 2024 T3 .090" DIM 501/2" X 201/2". FABRICATED NEW RAIN GUTTER FROM 2024 T3 .040" DIM 57" X 13/4" IAW EA 7-5330-135554. FABRICATED NEW L-1 DOOR SEAL DEPRESSOR FROM 2024 0 .040" DIM 271/2" X 2" IAW SRM 51-20-1 FIG 7. INSTALLED REPAIR DOUBLER, 2EA FREEZE PLUGS, RAIN GUTTER AND SEAL DEPRESSOR IAW EA 7-5330-135554.