What was found
NR 2 PYLON PYRAMID FITTING BASE PLATE UPPER SURFACE HAS CORROSION AROUND 4 EA MOUNT HOLES (APPROX 6 SQ IN TOTAL) REMOVED CORROSION FROM NR 2 PYLON PYRAMID FITTING BASE PLATE UPPER SURFACE. AROUND 4 EA HOLES IAW SRM 54-51-81 PAGE 101-102 FIG 104 NDT CHECK C/W IAW NTM 51-60-00NO DEFECTS NOTED. REPAIRED NR 2 PYLON IAW EA 6-5450-135226 BY FABRICATING 3 EA BUSHINGS.