What was found
CABIN FLOORBEAM TEE AT STA 345.0 BETWEEN LBL 24.75 AND LBL 45.5 HAS CORROSION. REMOVED CORROSION FROM T-CAP STA 345, LBL24-45, IAW SRM 51-10-02. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51, FIG 101, DETAIL III. ORIG MATERIAL .125 AFTER REWORK .106. L=20" W=.5 R & R UPPER TEE LBL 50 TO RBL 30 IAW SRM 53-00-51, FIG 201, REPAIR 3. CLASSIFIED CATEGORY "A" MAJOR REPAIR.