What was found
LT CREASE BEAM INBD CHORD HAS CORROSION BETWEEN BS 900 TO BS 1040 STRG 17L REMOVED CORROSION PER SRM 51-10-02. FOUND OUT OF LIMITS PER SRM 53-40-13, FIG.101, DETAIL 3, BEFORE: .070", AFTER: .050", LOSS: .020". REMOVED I/B CHORD BS 900-1040, S17L, PER SRM 51-40-02. RECEIVED NEW I/B CHORD BAC 1515-551. INSTALLED NEW I/B CHORD FROM BS 900-1040, S17L, PER SRM 51-40-02. MAJOR REPAIR.