What was found
AFT PIT FLOOR SUPPORT WEB BS 1600-1620 RBL 5.5 LOWER SECTION CORRODED. BLENDED OUT CORROSION ON WEB IN AFT CARGO STA 1600- 1620 AND CHECKED LIMITS, MATERIAL THICKNESS- 0.40, L=15", W=0.075, D=.10", AND FOUND OUT OF LIMIT IAW SRM 53-00-04, FIG 101. INSTALLED NEW WEB WITH PART NR 146N5451-9- N00307. ON AFT CARGO STA 1600-1620, RBL 5.5 IAW SRM 51-40-02. MAJOR REPAIR.