As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT PIT FLOOR STRUCTURE WEBS (2EA) BS 1500-1520 BL0-RBL 5.5 LOWER SECTION HAS CORROSION. REMOVED CORROSION FROM WEB STA 1500-1520 BL0 TO RBL 5.5 IAW SRM 51-10-02. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53, FIG 101 DETAIL V. ORIGINAL MATERIAL .032 AFTER REWORK .024 L=3.5 W=1.0. R & R WEB IAW SRM 51-40-02. CLASSIFIED CATEGORY "A" MAJOR REPAIR.