What was found
MCD CUTOUT UPPER SILL BS 605 & 615 HAS UPPER FLANGE WITH CRACK INDICATION AT (2 EA) RIVET HOLES. REMOVED DAMAGED MCD UPPER SILL, LOCATED & DRILLED NEW AFT SILL & INSTALLED NEW SILL UPPER SILL BEAM IAW EA 7-5310-135582.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MCD CUTOUT UPPER SILL BS 605 & 615 HAS UPPER FLANGE WITH CRACK INDICATION AT (2 EA) RIVET HOLES. REMOVED DAMAGED MCD UPPER SILL, LOCATED & DRILLED NEW AFT SILL & INSTALLED NEW SILL UPPER SILL BEAM IAW EA 7-5310-135582.