What was found
RIGHT WING INBOARD FLAP LOWER SURFACE IS CHAFED AT THE OUTBD HINGE . REPLACED RUB STRIPS IAW SRM 51-35-01, VOL II. REMOVED AND REINSTALLED PANEL ARC 3007-414 TO HAVE ACCESS IAW SRM 51-31-01, VOL II. DAMAGE ON CHAFED FLAP FOUND TO BE OUT OF LIMITS IAW SRM 57-00-01, VOL I. ORIGINAL THICNESS 0.041. REMAINING THICKNESS 0.022. FABRICATED DOUBLER AND FILLER. MATERIAL ID 2024-T3 0.050 IAW SRM 57-00-01, PG 12, VOL I. APPLIED ALODINE AND PRIMER IAW SRM 51-21-01, VOL II. INSTALLED DOUBLER AND FILLER IAW SRM 57-00-01, PG 12, VOL I; SRM 51-35-01, VOL II AND SRM 51-33-01, VIL II.