What was found
AFT PIT FRAME EXFOLIATED STA 1500, LBL 3 TO LBL 7. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS IAW SRM 53-00-07, FIG 101, DETAIL 1, P.103. REMOVED SPLICES, CLIP, TIE DOWN FITTINGS, FALSE CHORD, & FRAME, AND CUSP WEBS IAW SRM 51-40-02. LOCATED AND DRILLED NEW FRAME IAW DWG 146N1016. INSTALLED NEW FRAME AND RE-INSTALLED SPLICES, CLIP, TIE DOWN FITTINGS, FALSE CHORD, AND RE-INSTALLED CUSP WEBS IAW SRM 51-40-02 / 53-00-07 AND DWG 146N1016. MAJOR REPAIR.