What was found
MCD FWD HINGE SECTION HAS EXCESSIVE MOVEMENT AT HINGE AND PIN AREA. REMOVED UPPER HINGE SECTION, LOCATED & DRILLED NEW HINGE ASSY & INSTALLED NEW UPPER HINGE ASSY IAW SRM 51-30-2, SRM 51-30-8, SRM 51-10-2 & DWG NR 52FX1433.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MCD FWD HINGE SECTION HAS EXCESSIVE MOVEMENT AT HINGE AND PIN AREA. REMOVED UPPER HINGE SECTION, LOCATED & DRILLED NEW HINGE ASSY & INSTALLED NEW UPPER HINGE ASSY IAW SRM 51-30-2, SRM 51-30-8, SRM 51-10-2 & DWG NR 52FX1433.