What was found
CORROSION INSIDE CHANNEL OF STR 30, BS 950C TO 950F. REMOVED CORROSION IN CHANNEL OF STRINGER IAW SRM, REV 103, 51-10-6. COMPLIED WITH UT THICKNESS IAW NDTM PT 4, 51-00-00, FIG 2, AND MAPPED DAMAGE LOCATION IAW EA 7-5330-135588. ENGINEERING ANALYSIS FOUND NO REPAIR NECESSARY IAW EA 7-5330-135588. TREATED AND PRIMED AREA IAW SRM 51-10-2.