What was found
AFT CARGO BAY FRAME AT STA 1480 , S23R CHAFED. BLENDED CHAFE PER SRM 51-10-02 ORIG MATERIAL THICKNESS 0.063, MATERIAL LOSS 0.033, MATERIAL REMAIN 0.030 FOUND AREA OUT OF LIMITS PER SRM 53-00-07 INSTALLED REPAIR SPLICE PER SRM 51-40-02 AND 51-20-05 . FOUND OUT OF LIMITS PER SRM 53-00-07 DETAIL II FIG. 101 PAGE 107. FABRICATE REPAIR SPLICE ON TRAVELER T10/ 848596.