What was found
TWO POPPED RIVETS EXTERIOR FUSELAGE BS 1015 STRINGER 28R. REMOVED SECTION OF STRINGER 25 3/4" IN LENGTH AT BS 1015, STRINGER 28R IAW SRM, REV 103, 53-10-3, FIG 1 DETAIL 1. FABRICATED 2 STRINGER SECTIONS USING BAC1498-147, 7075-T6, 11" AND 14 3/4" LONG AND 2 SPLICES USING BAC1498-131, 7075-T6, 12" LONG EACH IAW SRM 53-10-3 FIG 1 DETAIL 1. INSTALLED STRINGER AND SPLICE SECTIONS IAW SRM 53-10-3, FIG 1, DETAIL 1.