What was found
REF EO F5450-7-5006 PT2 : STRUT 2 TO DIAGONAL BRACE FITTING INSP WORK INSTRUCTION E STEP 2 FAILED NDT. CRACK 0.020" AT 1.00 POS ON LOWER WEB AT HOLE FIG 3, CIRCLE 1. CRACK REPAIR CARRIED OUT IAW EA F-5450-139376 (PYLON STRUCTURE AD 2008-05-10 -NR2 PYLON LOWER SPAR WEB CRACK REPAIR). REPAIR IS CLASSIFIED AS MAJOR IAW GMM 6-2-100.