What was found
MAIN FLOOR SUPPORT FLANGE UPPER SURFACE OF SEAT TRACK GOUGED .5 SQ IN. LOCATED 4 IN FWD OF FR 17 AND 37IN RT OF CTR LINE. BLENDED GOUGE IN MAIN FLOOR SUPPORT FLANGE 4IN FWD OF FR17 AND37IN RT OF CTR LINE IAW SRM 51-74-10. CHECK LIMITS FOUND OUT OF LIMIT IAW SRM 51-23-10. REPAIRED SEAT TRACK IAW SRM 53-12-16.