What was found
MAIN DECK FLOOR, RT SHEAR WEB INBD SUPPORT ANGLE STA 1612-1628 HAS CORROSION. REMOVED CORROSION PER SRM 51-10-02. CHECKED LIMITS; ORIG. MATL.; .071", MATL. LOSS; .010", REMAINING; .061". FOUND TO BE OUT OF LIMITS PER SRM 53-60-13, FIG.101, DETAIL 3, P.103. REMOVED SHEAR WEB RT I/B SUPPORT PER SRM 51-40-02. FABRICATED SHEAR WEB RT I/B SUPPORT ANGLE, DRAWING 146N8722. TREATED / PRIMED PER SRM 51-20-01. INSTALLED NEW SHEAR WEB RT I/B SUPPORT ANGLE PER SRM 51-40-02. MAJOR REPAIR.