What was found
R-4 DOOR CUT OUT LOWER AFT ANGLE HAS CORROSION BS 1681, STG 17R BLENDED CORROSION ON SUPPORT ANGLE, ORIG MAT .063 / MAT LOSS .023, MAT REMOVED .040 FOUND TO BE OUT OF LIMITS IAW SRM 53-00-04, PAGE 103, DETAIL II SEC C-C. RECEIVED ANGLE ON MAE TRAVELER NR T10/848990. LOCATED & DRILLED ANGLE IAW SRM 51-40-05. INSTALLED ANGLE IAW SRM 51-40-02.