What was found
FLOOR SUPPORT CHANNEL STA 315, RBL25 CORRODED. REMOVED CORROSION TO FLOOR SUPPORT CHANNEL STA 315 RBL 25.0 IAW SRM 51-10-02 , CHECKED LIMITS ORIG MAT .050 MAT REMAINING .040 LOSS .010 , FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51, FIG 101 DETAIL III PAGE 103, REMOVED FLOOR SUPPORT CHANNEL IAW SRM 51-40-02, REMOVED ANGLE FOR FOM IAW SRM 51-40-02, FABRICATED NEW FLOOR SUPPORT CHANNEL ON TRAVELER T10/ 841103, LOCATED 7 DRILLED IAW SRM 51-40-02 TREATED & PRIMED & TOP COATED IAW SRM 51-20-01, INSTALLED FLOOR SUPPORT CHANNEL & ANGLE AT STA 315, RBL 25,0 PER 51-40-02.