What was found
MAIN DECK CARGO COMPT 10 IN AFT OF FR 14 , 57 IN. LT OF CTR LINE FLOOR SUPPORT CHANNEL HAS 4 SQ IN OF LEVEL 1 CORROSION ON UPPER SURFACE OF CHANNEL. REMOVED LEVEL 1 CORROSION. DURING CORROSION REMOVAL FOUND FLOOR SUPPORT CHANNEL OUT OF LIMITS. R & R FLOOR SUPPORT CHANNEL IAW SRM 51-40-21 AND SRM 51-40-44.