What was found
RT THS INBD FWD HOIST POINT FITTING BASE CRACKED, REF EO 6-5510-7-5001 PT2. PERFORMED EO 6-5510-7-5001, PT2 TO ACCOMPLISH THE WORK. (STAB-HORIZ-REPLACED METAL HOIST LUGS WITH PLASTIC LUGS) REPAIR CLASSFIED AS MINOR IAW GMM 6-2-100.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT THS INBD FWD HOIST POINT FITTING BASE CRACKED, REF EO 6-5510-7-5001 PT2. PERFORMED EO 6-5510-7-5001, PT2 TO ACCOMPLISH THE WORK. (STAB-HORIZ-REPLACED METAL HOIST LUGS WITH PLASTIC LUGS) REPAIR CLASSFIED AS MINOR IAW GMM 6-2-100.