What was found
UPON FRAME REMOVAL, FOUND DOUBLE DRILLED HOLES IN FRAME SPLICE, STA 950B, STR 24L. REMOVED PRODUCTION SPLICE/DOUBLER IAW SRM 51-30-2 FORMED NEW DOUBLER IAW SRM 51-20-1 FIG 7 INSTALLED NEW DOUBLER IAW SRM 51-30-2 REV 103.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
UPON FRAME REMOVAL, FOUND DOUBLE DRILLED HOLES IN FRAME SPLICE, STA 950B, STR 24L. REMOVED PRODUCTION SPLICE/DOUBLER IAW SRM 51-30-2 FORMED NEW DOUBLER IAW SRM 51-20-1 FIG 7 INSTALLED NEW DOUBLER IAW SRM 51-30-2 REV 103.