What was found
PREVIOUS EXTERNAL REPAIR DOUBLER LOCATED ON LT WING INBD FLAP UPPER SKIN AT RIB 10 TO 11 AND BETWEEEN THE REAR SPAR AND AUXILIARY SPAR ON STRINGERS 6 AND 7 MEASURES 5.4 IN X 6.6 IN. PREVIOUSLY INSTALLED REPAIR LOCATED AT LT WING INBD FLAP UPPER MAIN SKIN AT RIB 10 TO 11 AND BETWEEN THE REAR SPAR AND AUXILIARY SPAR ON STRINGER 6 AND 7 WAS DETERMINED NOT TO BE A VALID. REPAIR IAW ANY SRM BASED ON VISUAL EVALUATION. REMOVED EXISTING REPAIR AND INSTALLED A NEW REPAIR IAW EA 6-5750-135270.