What was found
SHORT EDGE MARGIN CONDITIONS FOUND IN 146N5044-4 FLOORBEAM UPPER FLANGE AT STA 1280, RBL 24.75 AND RBL 45.50 AT STA 1280, RBL 24.75 AND 45.5 FLOORBEAM UPPER FLANGE REPAIR WAS ACCOMPLISHED ON MAE EA 757-5365-16-F2762, REV- DATED JUN 24, 2010. MAJOR REPAIR.