What was found
FOUND LT AFT FUSELAGE SKIN DENT L=1.0", W=1.0", D=0.015" 6" FWD OF FR 78 AND STRINGER 26L. EVALUATED DENT AND FOUND TO BE NOT PERMISSABLE DUE TO DENT WAS LOCATED ON A STRINGER. STRINGER DIRECTLY OVER THE RIVET IAW SRM 53-10-12 PG 1. CUT OUT DAMAGED SKIN, VERIFIED MATERIAL THICKNESS, 2024T3 CLAD .071" AND .063" IAW SRM 53-10-12. FABRICATED DOUBLER AND FILLER IAW SRM 51-21-10 PAR. 2 AND INSTALLED REPAIR IAW SRM 53-10-12. ALODINED AND REPROTECTED AREA IAW SRM 51-74-10. ALL WORK PERFORMED UNDER WO 00048963.